Common Problems of LED Amusement Rides Lights

Common Problems of LED Amusement Rides Lights

Home / News / Common Problems of LED Amusement Rides Lights

Common Problems of LED Amusement Rides Lights

During the use of amusement rides lights, you may encounter a variety of common problems, which may involve multiple aspects such as electrical, installation, use and maintenance. The following are some common amusement rides lights problems and their possible causes and solutions:

1.Electrical failure


The bulb does not light up or flickers


Reason: The trigger is damaged, the power cord of the bulb circuit is broken, the relay does not attract or the contact is not in good contact, the ballast coil is short-circuited, etc.
Solution: Check and replace the damaged trigger, power cord, relay or ballast.


The bulb lights up for a while and then goes out


Reason: The bulb is aging or of poor quality, the fan does not turn or there is a lot of dust, the temperature control resistor is aging, the terminal is aging, etc.
Solution: Replace with a new bulb, clean the fan and the inside of the lamp, replace the temperature control resistor or the terminal.


Burn the bulb

Reason: The power supply voltage is too high, the circuit contact is not good and there is a momentary power failure, the bulb electrode terminal is not tight, the ballast coil is short-circuited, etc.
Solution: Check and adjust the power supply voltage, repair the problem of poor circuit contact, adjust the tightness of the bulb electrode terminal, and replace the damaged ballast.


2.Installation problems


The lamp is not installed firmly


Performance: The lamp is easy to shake or fall off after installation.
Solution: Make sure the lamp is installed firmly and use appropriate fixings and installation methods. For heavy lamps, use embedded lifting hooks or directly fix them from the roof with expansion anchor bolts.


Irrational installation position

Performance: The installation position of the lamp is too high or too low, which affects the lighting effect or poses a safety hazard.
Solution: According to the actual needs and lighting requirements of the amusement equipment, reasonably determine the installation position of the lamp.


3.Use and maintenance problems


Poor heat dissipation of lamps

Reason: Too much dust inside the lamp, blockage or damage of the heat dissipation system.
Solution: Clean the inside of the lamp regularly to keep the heat dissipation system unobstructed. For damaged heat dissipation systems, they should be repaired or replaced in time.


Insensitive lamp control

Reason: unstable control signal, damaged control device or improper setting.
Solution: Check and repair the control signal line, replace the damaged control device, and ensure that the control setting is correct.


Short lamp life


Reason: Harsh use environment, poor quality of bulbs or frequent switching, etc.
Solution: Improve the use environment of lamps, select reliable quality bulbs, and reduce unnecessary frequent switching operations.

4.Other problems


Damage to the appearance of lamps

Causes: collision, friction or corrosion, etc.
Solution: For minor appearance damage, appropriate repair materials can be used for repair; for serious damage, new lamps should be replaced.


Lamps do not match amusement equipment


Performance: The lighting effect of the lamps does not match the style or function of the amusement equipment.
Solution: According to the actual needs and lighting requirements of the amusement equipment, choose the appropriate type and specifications of lamps.


In summary, the common problems of Amusement Rides Lights involve electrical, installation, use and maintenance. In order to ensure the normal operation of the lamps and extend their service life, it is necessary to regularly inspect and maintain the lamps to detect and solve problems in a timely manner. At the same time, when installing and using lamps, attention should also be paid to following relevant safety regulations and operating requirements.

Amusement Rides Lights

Contact

  • Zhongshan Fun Amusement Lighting Co.,Ltd
  • No.2 Hefa Street, Tongmao Industrial Center, Dongsheng Town, Zhongshan City, Guangdong Province. China.
  • +86-760-89818230 +86-13823922950
  • +86-760-89818230
  • martin@fun-lighting.com

Newsletter

Sign up for the latest updates and news from our team.
Follow Us facebook twitter linkedin youtube Instagram
Top